2D. Connecting the TransVision
™
4 System
A. Connect AC power receptacle to a non-switched 120 VAC outlet using
the power cord provided with the TransVision
™
4 system.
B. Connect the digital input to the TransVision
™
4 processor using the cir-
cular connector of DVI cable.
NOTE: The TransVision
™
4 requires the use of a DWIN DVI cable between
the Projector and the Digital Video Processor to operate correctly !
C. The IR Receiver and the Power LED are located on top of the projector.
D. The POWER LED is a multi-purpose indicator:
• When the LED is dark the AC power to the unit is turned off.
• When the LED is flashing on and off, power is connected and the unit
is in the standby mode.
• When the LED is on the unit is powered on.
• When the LED is flashing fast, the projector lamp failed to ignite. The
lamp may have failed or overheated. In case the lamp is hot, wait ap
-
proximately 1 minute to turn the unit on. If the lamp has failed, contact
your DWIN dealer or DWIN for a replacement.